Á¤º¸Åë½Å±â±â
Á¤º¸ Åë½Å¿ë ¹Ìµð¾î±â±â (IEC/EN 62368-1)
¼Ò°³
Àü±â¾ÈÀü½ÃÇèÀÇ °æ¿ì º» ±âÁØÀº Á¤º¸Åë½Å ±â±â ¹× »ç¹«½Ç ±â±â ÀÌ¿Í À¯»çÇÑ Àü±â±â±â·Î¼Á¤°ÝÀü¾ÐÀÌ 600V ÀÌÇÏÀÎ
°ÍÀÇ ¾ÈÁ¤¼ºÀ» Ãë±ÞÇÕ´Ï´Ù. Á¤º¸±â±â (DSLM, Roulter, Computer, Fax, Printer µî), Power Supply, Battery
Charger, AC adaptor µîÀÇ Á¦Ç°±º¿¡ ´ëÇÏ¿© º¸´Ù ºü¸£°í, Æí¸®Çϰí, Á¤È®ÇÏ°Ô ±¹³» (KC)¸¦ ºñ·ÔÇÑ European
CE ¸¶Å©¿Í CB ÀÎÁõ ¹× ¹ÌÁÖ (UL)À» ȹµæÇÒ ¼ö ÀÖµµ·Ï, Á¦Ç°ÀÇ Á¢¼öºÎÅÍ Test °á°ú, ½ÂÀαîÁöÀÇ ¸ðµç ¼ºñ½º¸¦ Á¦°ø
ÇØ µå¸®°í ÀÖ½À´Ï´Ù.
¶ÇÇÑ BWS ½ÃÇè½ÇÀº UL ½ÃÇè¼ÒÀÇ withness test ±â°üÀ¸·Î¼ ULÀÎÁõÀ» ½±°Ô ÃëµæÇÒ ¼ö ÀÖÀ¸¸ç MET CBTLÀ»
ÅëÇÑ ÀÚüÀûÀÎ ½ÃÇèÀÌ °¡´ÉÇØ ±â°£°ú ºñ¿ëÀ» ´ÜÃà½Ãų ¼ö ÀÖ½À´Ï´Ù. ±¹³» KC (ÀüÀÚÆÄÀûÇÕµî·Ï)ÀÇ ÀüÀÚÆÄ ÀûÇÕ¼º
(EMC : EMI/EMS) ½ÃÇèÀÇ °æ¿ìÁ¤º¸±â±â¿¡ ´ëÇØ¼ Àü±â¡¤ÀüÀÚ±â±âÀÇ »ç¿ë±ÞÁõÀ¸·Î ÀÎÇØ ±â±â¿¡¼ ¹ß»ýÇÏ´Â ºÒ¿ä
ÀüÀÚÆÄ ¹× ´Ù¸¥ ±â±â³ª ¿ÜºÎÀÇ ÀüÆÄ¿¡ ÀÇÇÑ Åë½ÅÀåÇØ ¹× ±â±â ¿Àµ¿ÀÛÀ¸·Î ÀÎÇÑ ÀÎ¸í ¹× Àç»êÀÇ ÇÇÇØ¸¦ ÃÖ¼ÒÈÇÏ°í ±¹³» ÀüÆÄȯ°æÀ» º¸È£Çϱâ À§Çؼ Àû¿ëÇÕ´Ï´Ù.ÀüÀÚÆÄ
ÀûÇÕµî·ÏÀ» ¹Þ¾Æ¾ß ÇÏ´Â Á¤º¸±â±â¿¡´Â µ¥ÀÌÅÍ ¹× Åë½Å¸Þ¼¼ÁöÀÇ ÀԷ¡¤Ãâ·Â¡¤ÀúÀ塤°Ë»ö¡¤Àü¼Û ¶Ç´Â Á¦¾î µåÀÇ ÁÖ¿ä±â´É°ú Á¤º¸Àü¼Û¿ëÀ¸·Î ÀÛµ¿µÇ´Â 1°³ ÀÌ»óÀÇ ÅÍ¹Ì³ÎÆ÷Æ®¸¦
°®Ãá ±â±â·Î¼ 60º¼Æ®ÀÌÇÏÀÇ °ø±ÞÀü¾ÐÀ» °¡Áø ±â±â·Î´Â ÄÄÇ»ÅÍ¿Í ±× ÁÖº¯±â±â, ÅÍ¹Ì³ÎÆ÷Æ®°¡ ÀÖ´Â ÄÄÇ»ÅÍ ³»Àå ±¸¼ºÇ°¹× À¯¼±Åë½Å´Ü¸»±â±â·ù°¡ ÇØ´çµË´Ï´Ù.
- CE-LVD (2006/95/EC)´ë»ó±â±â
- The Directive applies to all electrical equipment designed for use with a voltage rating of between 50 and 1 000 V for alternating current and between 75 and 1 500 V for direct current. Voltage ratings refer to the voltage of the electrical input or output, not to voltages which may appear inside the equipment.
Following discussions with Member States the Commission has taken the position that the term ¡°designed for use with a voltage range¡± shall be understood at equipment having either a rated input voltage or a rated output voltage inside this voltage range.
Internally there may be higher voltages.
Battery operated equipment outside the voltage rating is obviously outside the scope of the LVD. Nevertheless, the accompanying battery-charger as well as equipment with integrated power supply unit within the voltage ranges of the Directive, are in the scope of the LVD. This applies also, in the case of battery-operated equipment with supply voltage rating under 50 V AC and 75 V DC, for their accompanying power supply unit (e.g. Notebooks).
However, the following are excluded from the scope of the ¡°Low Voltage¡± Directive:- - Electrical equipment for use in a potentially explosive atmosphere
- - Electrical equipment for radiology and medical purposes
- - Electrical parts for lifts
- - Electricity meters,
which are covered by other Community directives, and- - Plugs and socket outlets for domestic use
- - Electric fence controllers
- - Specialized electrical equipment, for use on ships, aircraft or railways which complies with the safety provisions drawn up by international bodies in which the Member States participate, which so far are not covered by any Community directive and therefore must not be CE marked
Á¦Ç°±º ¹× ÇØ´çÁ¦Ç°
Á¦Ç°±º | ÇØ´çÁ¦Ç° |
---|---|
Åë½Å±â±â | ¸ðµ©, Àüȱâ, ÆÑ½º |
Á¤º¸Ã³¸®±â±â | ÄÄÇ»ÅÍ, ¸ð´ÏÅÍ, ÇÁ¸°ÅÍ, Class B or A Digital device, ½ºÄ³³Ê, º¹ÇÕ±â |
»ç¹«±â±â | º¹»ç±â, °è»ê±â, ÀüÀÚ Å¸ÀÚ±â |
È¥Çչ̵ð¾î±â±â | CD-ROM/RW±â, µðÁöÅÐ Ä«¸Þ¶ó |
Åë½Å¸Á Àåºñ | Çãºê, ¸®ÇÇÅÍ, ¶ó¿ìÅÍ, ½ºÀ§Ä¡ |
¹«¼±¿ë Àåºñ | RF ¸ðµ© |
Àü¿ø°ø±ÞÀåÄ¡ | AC/DC ¾Æ´äÅÍ(ITE¿ë),DC/DC ÄÁ¹öÅÍ, AC/DC ÄÁ¹öÅÍ |
Àü±â¾ÈÀü½ÃÇè ½Åû½Ã
- ±â±âº»Ã¼ 5´ë
- ±â±â ¸Þ´º¾ó (°³¿ä,±¸¼º, »ç¾ç, »ç¿ë¹æ¹ý, ÁÖÀǹ®±¸µîÀÇ ³»¿ëÆ÷ÇÔ)
- ¶óº§
- ȸ·Îµµ
- ºÎǰ¸®½ºÆ® (Àü±âºÎǰ, ÇÃ¶ó½ºÆ½ºÎǰ, ±Ý¼ÓºÎǰ)
- ºÐÇØµµ
- PWB ÆÐÅϵµ
- ½ºÆå (transfomer, linefilter, motor)
- ºÎǰ (ÀÏÂ÷Ãø ¹× ÁÖ¿äºÎǰ¿¡ ´ëÇÏ¿© ÇØ´ç±Ô°Ý¿¡¼ ÀÎÁ¤ÇÏ´Â ºÎǰÀ» »ç¿ëÇØ¾ß ÇÔ)
- ex : Fuse, X-cap, Y-cap, varistor, opto-coupler, etc...)
ÀüÀÚÆÄÀûÇÕ¼º (EMC : EMI / EMS) ½ÃÇè ½Åû½Ã
- 01. KC (ÀüÀÚÆÄÀûÇÕµî·Ï)
-
- ½Ã·á 1´ë (±¸¼ºÀ» À§ÇÑ cable ¹× software°¡ Æ÷ÇԵǾî¾ß ÇÔ, Áï Á¦Ç°µ¿ÀÛÀ» simulation ½Ãų ¼ö ÀÖ¾î¾ß ÇÔ)
- »ç¿ëÀÚ ¼³¸í¼ (User¡¯s manual) Çѱۺ» (¼öÀÔ±â±âÀÇ °æ¿ì´Â ¿µ¹®º»µµ Æ÷ÇÔ) ; °³¿ä/±¸¼º/»ç¾ç/Á¶ÀÛ¹æ¹ýÀÌ ±âÀçµÇ¾î¾ß ÇÔ
- ¿µ¹® manual°ú ÇÑ±Û manualÀº matchingÀÌ µÇ¾î¾ß ÇÔ
- Á¾ÇÕ°èÅëµµ (Block diagram) : Á¦Ç°ÀÇ ±¸¼º ¹× °³¿ä¸¦ È®ÀÎÇϱâ À§ÇÔ
- »ç¾÷ÀÚµî·ÏÁõ »çº» (´ëÇ¥ÀÚÀÇ ÁֹιøÈ£ ±âÀç)
- ¿Ü±¹ Á¦Á¶ÀÚ ½ÂÀÎÀÏ °æ¿ì ±¹³» ´ë¸®ÀΰúÀÇ ´ë¸®ÀÎ °è¾à¼
- BWS Tech, ½ÃÇè½Åû¼,Á¤º¸Åë½Å±â±â ÀÎÁõ½Åû¼
- 02. FCC (part 15,18);
- »ùÇÃ 1´ë, FCC 731 form, FRN number, Grantee code, operational description
(±â±âµ¿ÀÛ¹æ¹ýÀ» ȸ·ÎÀÇ ±â´ÉÀ» ÅëÇØ¼ ±â¼úÇØ¾ß ÇÔ), Block Diagram(¿À½Ç·¹ÀÌÅÍÀÇ Á֯ļö¸¦ ³ªÅ¸³»¾ß ÇÔ), Schematics (ȸ·Îµµ), User¡¯s manual (»ç¿ëÀÚ ¼³¸í¼) - 03. CE (EN55032, EN55035)
- »ùÇà 1´ë, block diagram (¿À½Ã·¹ÀÌÅÍÀÇ Á֯ļö¸¦ ³ªÅ¸³»¾ß ÇÔ ), Schematics (ȸ·Îµµ), User¡¯s manual (»ç¿ëÀÚ ¼³¸í¼), part list (ºÎǰ ¸í¼¼¼)
Àû¿ë±Ô°Ý
- EN60950-1(CE)
- EN55032, EN55035, EN61000-3-2, EN61000-3-3 (CE)
- KN32, KN35 (KC)
- Part 15&18 (FCC)
- IEC60950, IEC60950-1 (CB,KC)
- UL60950-1
- IEC/EN 62368-1